EM TEST NX5

Multifunctional test generator for transients (EFT/Burst, Surge & Power Fail) up to 5.5 kV


The compact NX5 is a standalone generator which includes everything necessary to perform fully compliant tests. With separate power mains supply inputs, it allows the utilization of different EUT supply voltages for maximum flexibility.

The NX5 can be operated manually from the intuitive front touch screen or remotely via its built-in Ethernet, USB or optical interface. Failure inputs allow control of an ongoing test sequence based on the state of the EUT. Monitoring outputs (BNC) offer easy signal verification and measurements. For enhanced safety requirements, features like interlock and a warning lamp are available.

NX5 is the first generator that recognizes the connected EUT power configuration. Only coupling selections to active lines are enabled. Non existing lines will be disabled from the menu settings. Pre-programmed routines with common Test Standards allow maximum user convenience. Quick Start Test routines where parameters can be changed during susceptibility level evaluation are also available.

Add Items to Cart



Specifications

EFT/Burst Module

Standards

IEC/EN 61000-4-4, EN 61000-6-1, EN 61000-6-2

Test voltage

200 V - 5,500 V ± 10%; 100 V - 2,750 V ± 10% into 50 ohm

Pulse shape

5/50 ns into 50 ohm and 1,000 ohm

Rise time tr

5 ns ± 30% into 50 ohm; 5 ns ± 30% into 1,000 ohm

Pulse width td

50 ns ± 30% into 50 ohm; 50 ns -15/+100 ns into 1,000 ohm

Source impedance

50 ohm

Polarity

Positive/negative

Surge Wave/Combination Wave Module

Standards

IEC/EN 61000-4-5, IEC/EN 61000-6-1, IEC/EN 61000-6-2

Voltage

160 V - 5,000 V ± 10%

Pulse front time

1.2 us ± 30%

Pulse time to half value

50 us ± 20%

Current

Max. 2,500 A ± 10%

Pulse front time

8 us ± 20%

Pulse time to half value

20 us ± 20%

Polarity

Positive/negative/alternating

Event counter

1 - 99,999 or endless, selectable

Power Failure/Voltage Dips & Interrupts Module

Standards

IEC/EN 61000-4-11, IEC/EN 61000-4-29, IEC/EN 61000-6-1, IEC/EN 61000-6-2

Channel PF1/PF2

AC voltage: max. 300 V
AC current: max. 16 A
DC voltage: max. 300 V
DC current: max. 16 A

Frequency

16 Hz - 500 Hz and DC

Switching time

> 1 us < 5 us into a 100 ohm resistive load (SVP 100)

Inrush current

> 500 A

Protection

Both channels are protected against short-circuit conditions.
Product Tags